Electrical Machines Reactive power generated or delivered significantly depends on frequency. both 1 and 2. load angle. excitation. frequency. both 1 and 2. load angle. excitation. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Two synchronous generators operating in parallel 200 MW and 400 MW respectively. The drooping characteristics of their governors are identical as 4% from no load to full load. Consider the governors operating at 50Hz on no load. What is the operating frequency, if the load is 600 MW? 50 Hz 48.5 Hz 48 Hz 45 HZ 50 Hz 48.5 Hz 48 Hz 45 HZ ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The output power indicated on the name plate of any motor is always the Gross power. Power drawn in KW. Power drawn in KVA. Output power at the shaft. Gross power. Power drawn in KW. Power drawn in KVA. Output power at the shaft. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Damper winding is used to increase the load current. decrease the load current. both 1 and 2. suppress the hunting. increase the load current. decrease the load current. both 1 and 2. suppress the hunting. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A 6 pole lap connected DC generator with 480 conductors has armature resistance of 0.06 Ω. If the conductors are reconnected to from a wave winding other things remaining unchanged, the value of armature resistance will be 0.01 Ω. 0.54 Ω. 0.06 Ω. 0.54 Ω. 0.01 Ω. 0.54 Ω. 0.06 Ω. 0.54 Ω. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines If Ke is eddy current constant, Kf is form factor, f is supply frequency, Bm maximum flux density in core of transformer, the expression of eddy current loss in transformer, is given by Kef2KfBm2. Kef2Kf2Bm2. Kef2Kf2Bm. KefKf2Bm2. Kef2KfBm2. Kef2Kf2Bm2. Kef2Kf2Bm. KefKf2Bm2. ANSWER DOWNLOAD EXAMIANS APP