Process Equipment and Plant Design Pressure differential maintained across a continuous rotary vacuum filter is in the range of __________ mm Hg column. 100 to 150 250 to 500 600 to 700 50 to 100 100 to 150 250 to 500 600 to 700 50 to 100 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Tube height in a calendria type evaporator is normally less than __________ metres. 3.5 1 5.5 2 3.5 1 5.5 2 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Tube wall thickness depends on the cor-rosiveness of the fluids and their operating pressure & temperature and is specified by Birmingham wire gauge (B.W.G)-a number which varies from 8 to 18 with the numbers 14 and 16 being more commonly used. Outside diameter of tubes varies from about 15 to 50 mm; however a tube of less than __________ mm outside diameter is generally not recommended for fouling fluids. 38 19 28 16 38 19 28 16 ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design The centre to centre distance between two consecutive baffles in a shell and tube heat exchanger is called the baffle pitch or baffle spacing, which is more than 1/5th the I.D. of the shell. Which of the following is not a function of the baffles? To reduce the induced vibration in the tubes To increase the tube side heat transfer co-efficient by inducing turbulence To increase the residence time of shell side fluid To provide support to the tube bundle To reduce the induced vibration in the tubes To increase the tube side heat transfer co-efficient by inducing turbulence To increase the residence time of shell side fluid To provide support to the tube bundle ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design In packed towers provided with pall rings liquid redistributors are positioned at heights of every 6 metres or 5-10 times the column diameter, whichever is less. Maximum size of the pall rings should not exceed __________ of the column diameter. 1/5-1/10th 1/2 to 1/4th 1/20-1/30th 1/10-1/15th 1/5-1/10th 1/2 to 1/4th 1/20-1/30th 1/10-1/15th ANSWER DOWNLOAD EXAMIANS APP
Process Equipment and Plant Design Number of evaporators which can be used in service in a multiple effect evaporation system is limited by the Economic limit reached, when the plant cost exceeds the saving of steam Neither A nor B Both A & B Practical limit reached, due to low heat transfer rate because of inadequate temperature difference Economic limit reached, when the plant cost exceeds the saving of steam Neither A nor B Both A & B Practical limit reached, due to low heat transfer rate because of inadequate temperature difference ANSWER DOWNLOAD EXAMIANS APP