Power Systems The draw back of NR method as compare to Gauss-Seidel method is/are? large number of iterations large requirement of computer memory None of these both 1 and 2 large number of iterations large requirement of computer memory None of these both 1 and 2 ANSWER DOWNLOAD EXAMIANS APP
Power Systems Which of the following method is/are more reliable? Fast Decoupled Load Flow (FDLF) method All of these Newton Raphson (NR) method Gauss-Siedel (GS) method Fast Decoupled Load Flow (FDLF) method All of these Newton Raphson (NR) method Gauss-Siedel (GS) method ANSWER DOWNLOAD EXAMIANS APP
Power Systems Per unit of any quantity is defined as actual value of quantity /base value of quantity in same units base value of quantity /actual value of quantity in different units base value of quantity /actual value of quantity in same units actual value of quantity /base value of quantity in different units actual value of quantity /base value of quantity in same units base value of quantity /actual value of quantity in different units base value of quantity /actual value of quantity in same units actual value of quantity /base value of quantity in different units ANSWER DOWNLOAD EXAMIANS APP
Power Systems Advantage/s of per unit system as compare to absolute system? All of these memory required is less only one equation is required calculation time is less All of these memory required is less only one equation is required calculation time is less ANSWER DOWNLOAD EXAMIANS APP
Power Systems A transmission line has (2 + j4)Ω impedance, 100 MVA and base voltage is 10 KV. Find the per unit impedance value of transmission line? (2 + j4 ) pu (1 + j2 ) pu (0.5 + j1 ) pu (4 + j8 ) pu (2 + j4 ) pu (1 + j2 ) pu (0.5 + j1 ) pu (4 + j8 ) pu ANSWER DOWNLOAD EXAMIANS APP