Process Equipment and Plant Design
Pick out the wrong statement about routing of fluids in a shell and tube heat exchanger.

Lower flow rate fluid should be routed through the shell side
The corrosive and fouling fluid should be preferably routed through the tubes
The viscous fluid should be routed through the shell side
Higher pressure fluid stream should be routed through the shell side

ANSWER DOWNLOAD EXAMIANS APP

Process Equipment and Plant Design
Ponchon Savarit method is based on the use of enthalpy concentration diagram, which contains the bubble point curve (saturated liquid curve), dew point curve (saturated vapour curve) and equilibrium tie lines. As compared to McCabe-Thiele's method, this method

All of these
Facilitates direct calculation of heat load on reboiler & condenser from, the diagram used in this method
Accounts for the enthalpy changes in the process
Is more accurate in finding the number of equilibrium stages

ANSWER DOWNLOAD EXAMIANS APP