Electrical Machines Interpoles in a DC motor must be Series excited and should have the same polarity as that of the ahead main pole in the direction of rotation of armature. Shunt excited and should have the same polarity as that of the behind main pole in the direction of rotation of armature. Shunt excited and should have the same polarity as that of the ahead main pole in the direction of rotation of armature. Series excited and should have the same polarity as that of the behind main pole in the direction of rotation of armature. Series excited and should have the same polarity as that of the ahead main pole in the direction of rotation of armature. Shunt excited and should have the same polarity as that of the behind main pole in the direction of rotation of armature. Shunt excited and should have the same polarity as that of the ahead main pole in the direction of rotation of armature. Series excited and should have the same polarity as that of the behind main pole in the direction of rotation of armature. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines If dimension of all the parts of a synchorous generator and the number of field and armature turns are double, then generated voltage will change by a factor of 4. 1. 2. 8. 4. 1. 2. 8. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In case of 3 - Φ IM, plugging means pulling the motor directly on line without a rotor. interchanging two supply phases for quick stopping. starting the motor on load which is more than the rated load. locking of rotor due to harmonics. pulling the motor directly on line without a rotor. interchanging two supply phases for quick stopping. starting the motor on load which is more than the rated load. locking of rotor due to harmonics. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines It is an advisable to use auto transformer if the transformation ratio is 0.25. 0.5. near to 1. Greater than 1. 0.25. 0.5. near to 1. Greater than 1. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In DC generator, full form of MNA is what? Magnetic neutral armature co-ordinate. Magnetically no-load armature co-ordinate. Magnetic neutral axis. Magnetic no-load axis. Magnetic neutral armature co-ordinate. Magnetically no-load armature co-ordinate. Magnetic neutral axis. Magnetic no-load axis. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In dc machines, the field system has to be provided on stator unlike synchronous machines Where in it could be on any member, because it gives more uniform air-gap flux distribution dc machines are comparatively low rating machines. it reduces field structure iron losses commutator action is not possible otherwise it gives more uniform air-gap flux distribution dc machines are comparatively low rating machines. it reduces field structure iron losses commutator action is not possible otherwise ANSWER DOWNLOAD EXAMIANS APP