Concrete Technology and Design of Concrete Structures In case of hand mixing of concrete, the extra cement to be added is 20% 15% 5% 10% 20% 15% 5% 10% ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Which of the following R.C. retaining walls is suitable for heights beyond 6m? All of these counterfort type T-shaped wall L-shaped wall All of these counterfort type T-shaped wall L-shaped wall ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Minimum pitch of transverse reinforcement in a column is sixteen times the smallest diameter of longitudinal reinforcement bar to be tied forty-eight times the diameter of transverse reinforcement the least lateral dimension of the member lesser of the above three values sixteen times the smallest diameter of longitudinal reinforcement bar to be tied forty-eight times the diameter of transverse reinforcement the least lateral dimension of the member lesser of the above three values ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Examine the following statements :i) Factor of safety for steel should be based on its yield stress,ii) Factor of safety for steel should be based on its ultimate stress,iii) Factor of safety for concrete should be based on its yield stress,iv) Factor of safety for concrete should be based on its ultimate stress.The correct statements are (ii) and (iii) (i) and (iii) (i) and (iv) (ii) and (iv) (ii) and (iii) (i) and (iii) (i) and (iv) (ii) and (iv) ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Examine the following statements :i) Factor of safety for steel should be based on its yield stress,ii) Factor of safety for steel should be based on its ultimate stress,iii) Factor of safety for concrete should be based on its yield stress,iv) Factor of safety for concrete should be based on its ultimate stress.The correct statements are (i) and (iii) (ii) and (iii) (i) and (iv) (ii) and (iv) (i) and (iii) (ii) and (iii) (i) and (iv) (ii) and (iv) ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures According to IS: 456-1978, the column or the strut is the member whose effective length is greater than The least lateral dimension 2 times the least lateral dimension 3 times the least lateral dimension 4 times the least lateral dimension The least lateral dimension 2 times the least lateral dimension 3 times the least lateral dimension 4 times the least lateral dimension ANSWER DOWNLOAD EXAMIANS APP