DGVCL Exam Paper (11-12-2011) In carrier current protection, the purpose of the wave trap is for Trapping high frequency waves entering into generator/transformer unit. Tripping fault current All of these Trapping power frequency waves Trapping high frequency waves entering into generator/transformer unit. Tripping fault current All of these Trapping power frequency waves ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) DC series motors are best suited for traction work because Its torque is proportional to the square of the armature current and speed is inversely proportional to torque Its torque is proportional to the square of the armature current and speed is directional proporational to torque Torque and speed are inversely proportional to the square of the armature current Torque and speed are proportional to the square of the armature current Its torque is proportional to the square of the armature current and speed is inversely proportional to torque Its torque is proportional to the square of the armature current and speed is directional proporational to torque Torque and speed are inversely proportional to the square of the armature current Torque and speed are proportional to the square of the armature current ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Torque in d.c motor = k* φ * IaIn series motor φ α IaTα I²N α 1/φN α 1/T
DGVCL Exam Paper (11-12-2011) Buchholz relay causes Tripping for minor faults and alarm for major faults Tripping for major faults and alarm for minor faults Alarm for both major and minor faults Tripping for both major and minor faults Tripping for minor faults and alarm for major faults Tripping for major faults and alarm for minor faults Alarm for both major and minor faults Tripping for both major and minor faults ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Different computers are connected to a LAN by a cable and a Special wires Telephone line Modem Interface card Special wires Telephone line Modem Interface card ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) If the voltage at the two ends of a line are 132 kV, and its reactance is 40 Ω, the stability limit of the line is 217.8 MW 500 MW 435.6 MW 251.5 MW 217.8 MW 500 MW 435.6 MW 251.5 MW ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) If the excitation of a synchronous generator fails, it acts as a Induction generator Synchronous motor Synchronous generator Induction motor Induction generator Synchronous motor Synchronous generator Induction motor ANSWER EXPLANATION DOWNLOAD EXAMIANS APP if excitation of synchronous generator fails, operate as induction motor