Electrical Machines
In the 3-phase induction motor, the resultant flux is of a constant nature and is

 3/2 times maximum value of flux due to any phase
 3 times maximum value of flux due to any phase
 1/2 times maximum value of flux due to any phase
 equal to φm, where φm is the maximum flux due to any phase

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
Two synchronous generators operating in parallel 200 MW and 400 MW respectively. The drooping characteristics of their governors are identical as 4% from no load to full load. Consider the governors operating at 50Hz on no load. How will the machine share, if the load is 600 MW?

 230.7 MW and 369.23 MW respectively
 generator 1 gets over load
 generator 2 gets over load
 200 MW and 400MW respectively

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
The factors that are responsible for decrease in terminal voltage of a shunt generator are

 armature resistance, effect of armature reaction.
  reduction in field current, effect of armature reaction, armature.
 armature resistance, inter poles, armature.
  armature resistance, effect of armature reaction.