DGVCL Exam Paper (11-12-2011) In a power plant, a reserve generating capacity which is not in service but is in operation is known as Cold reserve Firm power Spinning reserve Hot reserve Cold reserve Firm power Spinning reserve Hot reserve ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Which of the following correctly represents the sequence of operations of isolator, circiut breaker and earthing switch while opening a circuit? Open isolator close circuit breaker-open earthing switch Close circuit breaker-close isolator - open earthing switch Open circuit breaker-open isolator-close earthing switch Close earthing switch - open ciruit- breaker-open islotor Open isolator close circuit breaker-open earthing switch Close circuit breaker-close isolator - open earthing switch Open circuit breaker-open isolator-close earthing switch Close earthing switch - open ciruit- breaker-open islotor ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) The corona effect can be minimized by increasing Spacing between the conductors Diameter of the conductor The length of the conductor Both spacing between the conductors and diameter of the conductor Spacing between the conductors Diameter of the conductor The length of the conductor Both spacing between the conductors and diameter of the conductor ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Corona can be reduced by using large size of conductor, bundle conductor and hollow conductor.
DGVCL Exam Paper (11-12-2011) Which lightning stroke is most dangerous? Indirect stroke on conductor Direct stroke on ground wire Direct stroke on line conductor Direct stoke on tower top Indirect stroke on conductor Direct stroke on ground wire Direct stroke on line conductor Direct stoke on tower top ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Rated making capacity of a ciruit breaker is equal to √2 X rated symmetrical breaking capacity 2.55 X rated symmetrical breaking capacity 1.11 X rated symmetrical breaking capacity Rated symmetrical breaking capacity √2 X rated symmetrical breaking capacity 2.55 X rated symmetrical breaking capacity 1.11 X rated symmetrical breaking capacity Rated symmetrical breaking capacity ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) The transient stability of a power system can be improved by Excitation control Single pole switching of circuit breakers Phase shifting transformer Increasing the turbine valve opening Excitation control Single pole switching of circuit breakers Phase shifting transformer Increasing the turbine valve opening ANSWER DOWNLOAD EXAMIANS APP