Electrical Machines For the above problem, find the induced voltage of an alternator of it is to deliver a load of 100 A at power factor of 0.8 lagging with terminal voltage of 200 V. 220 V. 222 V. 225 V. 230 V. 220 V. 222 V. 225 V. 230 V. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In dc machines, 1. reactance voltage is proportional to armature current 2.reactance voltage is proportional to core length 3.reactance voltage is due to self-flux of the coil undergoing commutation 4. armature-cross flux is neutralized by interpolar flux 5. interpolarmmf is more than armature mmf in the interpolar zone From these, the correct answer is 1, 2, 3, 4 1, 3, 5 1, 2, 5 2, 3, 4 1, 2, 3, 4 1, 3, 5 1, 2, 5 2, 3, 4 ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines If in DC Shunt Motor the flux is reduced suddenly to zero, then the motor will attain dangerously high speed. the motor will come to stop. the speed of motor will be reduced. the armature current will reduce. the motor will attain dangerously high speed. the motor will come to stop. the speed of motor will be reduced. the armature current will reduce. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A three phase 400 V, 6 pole, 50 Hz, squirrel cage induction motor is running at a slip of 5%. The speed of stator magnetic field with respect to rotor magnetic field and speed of rotor w.r.t stator magnetic field are zero , - 50 rpm. 1000 rpm, - 50 rpm. 1000 rpm, 950 rpm. zero, 950 rpm. zero , - 50 rpm. 1000 rpm, - 50 rpm. 1000 rpm, 950 rpm. zero, 950 rpm. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In a 3-phase induction motor, torque and supply voltage are related as T∝ V² T ∝ 1/V² T ∝ V T ∝ 1/V T∝ V² T ∝ 1/V² T ∝ V T ∝ 1/V ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines For a transformer to be tested at full load conditions but consuming only losses from the main, we do load test None of these back to back test OC and SC tests load test None of these back to back test OC and SC tests ANSWER DOWNLOAD EXAMIANS APP