Electrical Machines Due to magnetic saturation, the flux per pole in a DC machine without brush shift decreases in generators and increases in motor with load. increases in both the generators and the motors with load. increases in generators but decreases in motor with load. decreases in both generators and the motors with load. decreases in generators and increases in motor with load. increases in both the generators and the motors with load. increases in generators but decreases in motor with load. decreases in both generators and the motors with load. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A DC series motor must started on no load because it would Draw more current without producing sufficient torque. Not develop starting torque. Fail to start without load. Run at dangerously high speed. Draw more current without producing sufficient torque. Not develop starting torque. Fail to start without load. Run at dangerously high speed. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The factors that are responsible for decrease in terminal voltage of a shunt generator are reduction in field current, effect of armature reaction, armature. armature resistance, effect of armature reaction. armature resistance, inter poles, armature. armature resistance, effect of armature reaction. reduction in field current, effect of armature reaction, armature. armature resistance, effect of armature reaction. armature resistance, inter poles, armature. armature resistance, effect of armature reaction. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A 4 pole wave wound dc motor having flux per pole of 9.56 X 10-3 Wb contains 460 armature conductors. Calculate the back emf produced when it is running at a speed of 1500 rpm. 240 volt. 440 volt. 230 volt. 220 volt. 240 volt. 440 volt. 230 volt. 220 volt. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In dc machines, 1. reactance voltage is proportional to armature current 2.reactance voltage is proportional to core length 3.reactance voltage is due to self-flux of the coil undergoing commutation 4. armature-cross flux is neutralized by interpolar flux 5. interpolarmmf is more than armature mmf in the interpolar zone From these, the correct answer is 1, 3, 5 1, 2, 3, 4 2, 3, 4 1, 2, 5 1, 3, 5 1, 2, 3, 4 2, 3, 4 1, 2, 5 ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A 4 pole dc motor with armature winding resistance of 0.6 ohm receives a supply of 230 Volt. If the back emf produced during running condition is equal to 210 volt. Calculate the current flowing through the armature at this point. 44.47 Amp. 29 Amp. 33.33 Amp. 43 Amp. 44.47 Amp. 29 Amp. 33.33 Amp. 43 Amp. ANSWER DOWNLOAD EXAMIANS APP