DGVCL Exam Paper (11-12-2011) DC series motors are best suited for traction work because Its torque is proportional to the square of the armature current and speed is directional proporational to torque Its torque is proportional to the square of the armature current and speed is inversely proportional to torque Torque and speed are proportional to the square of the armature current Torque and speed are inversely proportional to the square of the armature current Its torque is proportional to the square of the armature current and speed is directional proporational to torque Its torque is proportional to the square of the armature current and speed is inversely proportional to torque Torque and speed are proportional to the square of the armature current Torque and speed are inversely proportional to the square of the armature current ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Torque in d.c motor = k* φ * IaIn series motor φ α IaTα I²N α 1/φN α 1/T
DGVCL Exam Paper (11-12-2011) The corona effect can be minimized by increasing Diameter of the conductor The length of the conductor Both spacing between the conductors and diameter of the conductor Spacing between the conductors Diameter of the conductor The length of the conductor Both spacing between the conductors and diameter of the conductor Spacing between the conductors ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Corona can be reduced by using large size of conductor, bundle conductor and hollow conductor.
DGVCL Exam Paper (11-12-2011) If the excitation of a synchronous generator fails, it acts as a Synchronous generator Synchronous motor Induction motor Induction generator Synchronous generator Synchronous motor Induction motor Induction generator ANSWER EXPLANATION DOWNLOAD EXAMIANS APP if excitation of synchronous generator fails, operate as induction motor
DGVCL Exam Paper (11-12-2011) First zone distance relay protects the transmission line section upto Its full length 50 % of its full length 80 % of its full length 25 % of its full length Its full length 50 % of its full length 80 % of its full length 25 % of its full length ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Which motor is used to start heavy loads? Cumulatively compounded motor Differentially compounded motor Series motor Shunt motor Cumulatively compounded motor Differentially compounded motor Series motor Shunt motor ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Torque in d.c motor = k* φ * IaIn series motor φ α IaTα I²starting torque of dc series motor is high
DGVCL Exam Paper (11-12-2011) The circuit breaker generally used in railway traction is Vacuum CB Minimum Oil CB Bulk Oil CB Air break CB Vacuum CB Minimum Oil CB Bulk Oil CB Air break CB ANSWER DOWNLOAD EXAMIANS APP