Refrigeration and Air Conditioning Air refrigeration cycle is used in Commercial refrigerators Gas liquefaction Air conditioning Domestic refrigerators Commercial refrigerators Gas liquefaction Air conditioning Domestic refrigerators ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The ratio of actual mass of water vapour in a given volume of moist air to the mass of water vapour in the same volume of saturated air at the same temperature and pressure, is called Relative humidity Degree of saturation Absolute humidity Humidity ratio Relative humidity Degree of saturation Absolute humidity Humidity ratio ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The bypass factor of a cooling coil decreases with Increase in fin spacing and decrease in number of rows Decrease in fin spacing and increase in number of rows Increase in fin spacing and increase in number of rows Decrease in fin spacing and decrease in number of rows Increase in fin spacing and decrease in number of rows Decrease in fin spacing and increase in number of rows Increase in fin spacing and increase in number of rows Decrease in fin spacing and decrease in number of rows ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Dry bulb temperature is the temperature of air recorded by a thermometer, when None of the listed here Its bulb is surrounded by a wet cloth exposed to the air The moisture present in it begins to condense It is not affected by the moisture present in the air None of the listed here Its bulb is surrounded by a wet cloth exposed to the air The moisture present in it begins to condense It is not affected by the moisture present in the air ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning It is desired to condition the outside air from 70% relative humidity and 45° C dry bulb temperature to 50% relative humidity and 25° C dry bulb temperature (room condition). The practical arrangement will be Dehumidification and pure sensible cooling Cooling and dehumidification Dehumidification Cooling and humidification Dehumidification and pure sensible cooling Cooling and dehumidification Dehumidification Cooling and humidification ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The operating temperature of a cold storage is -2°C. The heat leakage from the surrounding is 30 kW for the ambient temperature of 40°C. The actual C.O.P. of refrigeration plant used is one fourth that of ideal plant working between the same temperatures. The power required to drive the plant is 1.86 kW 18.6 kW 3.72 kW 7.44 kW 1.86 kW 18.6 kW 3.72 kW 7.44 kW ANSWER DOWNLOAD EXAMIANS APP