MGVCL Exam Paper (30-07-2021 Shift 2)
A single phase 240 V, 1 kW heater is connected across single phase 240 V, 50 Hz supply through an SCR. For firing angle delay of 90˚, calculate the power absorbed in the heater element.

300 W
275 W
225 W
250 W

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
In a test by Murray loop for ground fault on 600 m of cable having a resistance of 1.5 Ω/km, the faulty cable is looped with a sound cable of the same length and area of cross section. If the ratio of the other two arms of the testing network at balance is 3 : 1, find the distance of the fault from the testing end of cables.

400 m
100 m
200 m
300 m

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
Which one of the following statement is TRUE?

In the cables, the location of fault is usually found out by comparing the capacitances of insulated conductors.
The current carrying capacity of cables in DC is less than that in AC.
In the cables, sheaths are used to provide enough strength.
Underground cables are laid at sufficient depth to avoid being unearthed easily due to removal of soil.

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
In a single phase energy meter, the shunt electromagnet is energized by a ____of ____

current coil, thick wire of few turns
pressure coil, thin wire of more turns
current coil, thin wire of more turns
pressure coil, thick wire of few turns

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP