A single phase 240 V, 1 kW heater is connected across single phase 240 V, 50 Hz supply through an SCR. For firing angle delay of 90˚, calculate the power absorbed in the heater element.

225 W
300 W
275 W
250 W

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
In a test by Murray loop for ground fault on 600 m of cable having a resistance of 1.5 Ω/km, the faulty cable is looped with a sound cable of the same length and area of cross section. If the ratio of the other two arms of the testing network at balance is 3 : 1, find the distance of the fault from the testing end of cables.

200 m
100 m
400 m
300 m

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
The magnitude of the generator earth-fault current is limited by

inserting suitable resistance in neutral grounding circuit
controlling field exciter
using higher rating CTs
inserting the stabilizing resistance in series with the relay

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
Which of the following does the term 'feeder automation' include?

substation reactive power control
All of these
automatic reclosing
feeder remote point voltage control

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP