MGVCL Exam Paper (30-07-2021 Shift 2)
A single phase 240 V, 1 kW heater is connected across single phase 240 V, 50 Hz supply through an SCR. For firing angle delay of 90˚, calculate the power absorbed in the heater element.

300 W
275 W
225 W
250 W

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
If no load is connected to solar PV system,

its voltage will go on increasing till its breakdown
it will stop absorbing light
it will dissipate energy in the panel and increase its temperature
it will start reflecting the light

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

MGVCL Exam Paper (30-07-2021 Shift 2)
Consider a solar PV plant with the following specific conditions: Analysis period: 1 year
Measured average solar irradiation intensity in 1 year: 120 kWh/m²
Generator area of the PV plant: 10 m²
Efficiency factor of the PV modules: 15%
Electrical energy actually exported by plant to grid: 110 kWh
Calculate the performance ratio.

0.5111
0.7111
0.8111
0.6111

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP