DGVCL Exam Paper (11-12-2011) A device connected to the computer which converts digital signals to analog and vice-versa is CPU Keyboard UPS Modem CPU Keyboard UPS Modem ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) The bus bar zone faults are generally Double line to ground faults Single line to ground faults Three phase short ciruits Phase to phase faults Double line to ground faults Single line to ground faults Three phase short ciruits Phase to phase faults ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) It is difficult interrupt a capacitive current because Current magnitude is very small The restriking voltage can be high Stored energy in the capacitor is very high It has a leading power factor Current magnitude is very small The restriking voltage can be high Stored energy in the capacitor is very high It has a leading power factor ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) Due to skin effect Uniform current flows through the conductor Portion of the conductor near the surface carries less current and the core of the conductor carries more current Portion of the conductor near the surface carries more current and the core of the conductor carries less current Current flows through the half cross section of the conductor Uniform current flows through the conductor Portion of the conductor near the surface carries less current and the core of the conductor carries more current Portion of the conductor near the surface carries more current and the core of the conductor carries less current Current flows through the half cross section of the conductor ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Skin Effect:tendency of the current to crowd near the conductor surface.Skin effect is proportional to frequency, conductor diameter and permiability. Skin effect increases effective resistance of conductor.In DC, no skin effect.
DGVCL Exam Paper (11-12-2011) The corona effect can be minimized by increasing The length of the conductor Both spacing between the conductors and diameter of the conductor Diameter of the conductor Spacing between the conductors The length of the conductor Both spacing between the conductors and diameter of the conductor Diameter of the conductor Spacing between the conductors ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Corona can be reduced by using large size of conductor, bundle conductor and hollow conductor.
DGVCL Exam Paper (11-12-2011) If the fault current is 2000 A, the relay plug setting is 50% and the CT ratio is 400/5, the plug setting multiple will be 25 10 15 50 25 10 15 50 ANSWER DOWNLOAD EXAMIANS APP