MGVCL Exam Paper (30-07-2021 Shift 3)
A delta-connected balanced three-phase load is supplied from a three phase, 400 V supply. The line current is 20 Aand the power taken by the load is 10 kW. Find the power consumed if the same load is connected in star.
Type B MCB: Type B devices are generally suitable for domestic applications. They are designed to trip at fault currents of 3 - 5 times rated current.
Type C MCB: Type C devices are the normal choice for commercial and industrial applications These devices are designed to trip at 5 - 10 times rated current
Type D MCB: The Type D devices have more limited applications, normally in industrial use where high inrush currents may be expected. Type D devices are designed to trip at 10 - 20 times.
For the cut-in speed is the point at which the wind turbine is able to generate power. Between the cut-in speed and the rated speed, where the maximum output is reached, the power output will increase cubically with wind speed. Pmax directly propotional to cubical of wind speed. So, by double the speed of wind power will be increased by 8 times.
Bus Type - Known Parameter - Unknown Parameter Load Bus -P, Q - V, phase angle Generator Bus - P, V (magnitude) - Q, Voltage phase angle Slack Bus Voltage - magnitude and phase angle - P, Q
Dynamic voltage restoration (DVR) is a method of overcoming voltage sags and swells that occur in electrical power distribution. Devices used for DVR include static var devices, which are series compensation devices that use voltage source converters (VSC). The DVR is used to inject three phase voltage in series and in synchronism with the network voltages in order to compensate voltage disturbances with a benefit of active /reactive power control.