Electrical Machines
A compound dc generator is delivering full load current at a terminal voltage of 230 V. Its series-field winding gets short circuited. If its terminal voltage 1. becomes more than 230 V, it is overcompounded generator 2. becomes more than 230 V, it is differentially compounded generator 3. becomes less than 230 V, it is overcompounded generator 4. becomes less than 230 V, it is differentially compounded generator 5. becomes less than 230 V, it is level compounded generator From these, the correct answer is

 2, 3, 5
 1, 4, 5
 1, 4
 2,3

ANSWER DOWNLOAD EXAMIANS APP

Electrical Machines
The introduction of interpoles in between the main poles improves the performance of a dc machine, because

 the flux waveform is improved with reduction in harmonics
 the inequality of air-gap flux on the top and bottom halves of the armature is removed
 a counter-emf is induced in the coil undergoing commutation
 the interpoles produce additional flux to augment the developed torque

ANSWER DOWNLOAD EXAMIANS APP