Measurement and Instrumentation Why is a MISC meter not recommended for DC measurement? The error is high due to eddy current effect The meter is calibrated for AC and it’s error for DC would be high The error is high due to hysteresis effect The meter does not respond to DC signals The error is high due to eddy current effect The meter is calibrated for AC and it’s error for DC would be high The error is high due to hysteresis effect The meter does not respond to DC signals ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The resistance of a circuit is measured from the relation R= P/I2, where P is the power fed into the circuit and I is the current flowing through it. If the limiting errors in the measurement of power and current are respectively ± 1.0% and ± 1.0%, then what will be the limiting error in measurement of resistance ? ± 3.0% ± 1.5% ±0.5% ±3.5% ± 3.0% ± 1.5% ±0.5% ±3.5% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A sampling wattmeter is used to measure the average power of a load. The peak to peak voltage of a square wave is 10 V and the current is triangular wave of 5 Amp P-P as shown in the figure. The period is 20 ms. The reading in W will be 50 W. 25 W. 100 W. 0 W. 50 W. 25 W. 100 W. 0 W. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation Consider the following statement - 1. The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the current coil. 2. The compensating coil of a low power factor wattmeter compensates the effect of the impedance of the voltage coil circuit. Both 1 and 2 are false. Both 1 and 2 are true. 1 is false but 2 is true. 1 is true but 2 is false. Both 1 and 2 are false. Both 1 and 2 are true. 1 is false but 2 is true. 1 is true but 2 is false. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A DC potentiometer is the best means available for the measurement of DC voltage because It is possible to standardize before a measurement is undertaken. The precision in measurment is independent of the type of the defector used. None of above. It is based on null balance technique. It is possible to standardize before a measurement is undertaken. The precision in measurment is independent of the type of the defector used. None of above. It is based on null balance technique. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The use of thermocouple meters for AC measurement leads to scale which is logarithmic. linear. square law. expontial. logarithmic. linear. square law. expontial. ANSWER DOWNLOAD EXAMIANS APP