Refrigeration and Air Conditioning The superheated vapour region, in a pressure enthalpy chart, is represented by the space To the right of saturated liquid line To the left of saturated liquid line Between the saturated liquid line and saturated vapour line None of these To the right of saturated liquid line To the left of saturated liquid line Between the saturated liquid line and saturated vapour line None of these ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The bypass factor, in case of sensible cooling of air, is given by (where td₁ = Dry bulb temperature of air entering the cooling coil, td₂ = Dry bulb temperature of air leaving the cooling coil, and td₃ = Dry bulb temperature of the cooling coil) (td₁ -td₃)/( td₂ -td₃) (td₂ -td₃)/( td₁ -td₃) (td₃ -td₂)/( td₁ -td₃) (td₃ -td₁)/( td₂ -td₃) (td₁ -td₃)/( td₂ -td₃) (td₂ -td₃)/( td₁ -td₃) (td₃ -td₂)/( td₁ -td₃) (td₃ -td₁)/( td₂ -td₃) ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The bypass factor for a cooling coil Decreases with increase in velocity of air passing through it May increase or decrease with increase in velocity of air passing through it depending upon the condition of air entering Increases with increase in velocity of air passing through it Remains unchanged with increase in velocity of air passing through it Decreases with increase in velocity of air passing through it May increase or decrease with increase in velocity of air passing through it depending upon the condition of air entering Increases with increase in velocity of air passing through it Remains unchanged with increase in velocity of air passing through it ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The conditioned air supplied to the room must have the capacity to take up Room sensible heat load only None of the listed here Both room sensible heat and latent heat loads Room latent heat load only Room sensible heat load only None of the listed here Both room sensible heat and latent heat loads Room latent heat load only ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of -23°C, then the Carnot COP will be 6 5 0.2 1.2 6 5 0.2 1.2 ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A refrigerant compressor is used to Raise the pressure of the refrigerant All of these Circulate the refrigerant through the refrigerating system Raise the temperature of the refrigerant Raise the pressure of the refrigerant All of these Circulate the refrigerant through the refrigerating system Raise the temperature of the refrigerant ANSWER DOWNLOAD EXAMIANS APP