Process Equipment and Plant Design
Pick out the wrong statement about the design of seive plate column and the bubble cap column.

Weir height for a bubble cap plate column is the same as that for a seive plate column
The downcomer design and the residence time in the downcomer is almost same for seive plate and bubble cap columns
Weir length for a bubble cap plate is the same as that for the seive plate
Weir height in case of a bubble cap plate ranges from 50 to 150 mm and is higher than the seive plate

ANSWER DOWNLOAD EXAMIANS APP

Process Equipment and Plant Design
Pick out the wrong statement pertaining to the design of the distillation column.

None of these
Generally, a skirt clerance of 0.5" to 1.5' is recommended to prevent plugging of the slots by residue build up
If sufficient slot area is not provided, the gas may pass through the skirt clearance
The purpose of the slot is to disperse the gas into the liquid in the form of small bubbles

ANSWER DOWNLOAD EXAMIANS APP