Refrigeration and Air Conditioning The evaporator changes the low pressure liquid refrigerant from the expansion valve into Low pressure vapour refrigerant High pressure liquid refrigerant Low pressure liquid and vapour refrigerant None of these Low pressure vapour refrigerant High pressure liquid refrigerant Low pressure liquid and vapour refrigerant None of these ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The operating temperature of a cold storage is -2°C. The heat leakage from the surrounding is 30 kW for the ambient temperature of 40°C. The actual C.O.P. of refrigeration plant used is one fourth that of ideal plant working between the same temperatures. The power required to drive the plant is 1.86 kW 3.72 kW 7.44 kW 18.6 kW 1.86 kW 3.72 kW 7.44 kW 18.6 kW ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning One of the purposes of sub cooling the liquid refrigerant is to Ensure that only liquid and not the vapour enters the expansion (throttling) valve Reduce compressor overheating Increase cooling effect Reduce compressor discharge temperature Ensure that only liquid and not the vapour enters the expansion (throttling) valve Reduce compressor overheating Increase cooling effect Reduce compressor discharge temperature ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning For proper refrigeration in a cabinet, if the temperature and vapour pressure difference between cabinet and atmosphere is high, then Bigger cabinet should be used Perfectly tight vapour seal should be used Refrigerant with lower evaporation temperature should be used Smaller cabinet should be used Bigger cabinet should be used Perfectly tight vapour seal should be used Refrigerant with lower evaporation temperature should be used Smaller cabinet should be used ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In vapour compression cycle, the condition of refrigerant is very wet vapour After passing through the condenser Before passing through the condenser Before entering the compressor After passing through the expansion or throttle valve After passing through the condenser Before passing through the condenser Before entering the compressor After passing through the expansion or throttle valve ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Dry bulb temperature is the temperature of air recorded by a thermometer, when Its bulb is surrounded by a wet cloth exposed to the air None of the listed here It is not affected by the moisture present in the air The moisture present in it begins to condense Its bulb is surrounded by a wet cloth exposed to the air None of the listed here It is not affected by the moisture present in the air The moisture present in it begins to condense ANSWER DOWNLOAD EXAMIANS APP