MGVCL Exam Paper (30-07-2021 Shift 1)
The current flowing to a balanced delta connected load through line 'a' is 15 A when the conductor of line 'b' is open. With the current in line 'a' as reference, compute the symmetrical components of the line currents. Assume the phase sequence of 'abc'.
The magnitude of earth fault current for a given fault position within a winding demands upon the winding connections and method of neutral grounding. Earth fault protection for an electric motor is provide by instantaneous relay having a setting of approximately 30% of motor rated current in the residual circuits of two CTs and with ground wire.
For lagging power factor = (IR*cosφ + Ixsinφ)/Vr For leading power factor = (IR*cosφ - Ixsinφ)/Vr Zero voltage regulation occurs on leading power factor only.