Refrigeration and Air Conditioning The conditioned air supplied to the room must have the capacity to take up Room sensible heat load only Both room sensible heat and latent heat loads Room latent heat load only None of the listed here Room sensible heat load only Both room sensible heat and latent heat loads Room latent heat load only None of the listed here ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The boiling point of ________ is 10.5°C. Ammonia Carbon dioxide R-12 Sulphur dioxide Ammonia Carbon dioxide R-12 Sulphur dioxide ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In vapour compression cycle using NH₃ as refrigerant, initial charge is filled at Low pressure side near receiver High pressure side close to receiver Delivery of compressor Suction of compressor Low pressure side near receiver High pressure side close to receiver Delivery of compressor Suction of compressor ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The operating temperature of a cold storage is -2°C. The heat leakage from the surrounding is 30 kW for the ambient temperature of 40°C. The actual C.O.P. of refrigeration plant used is one fourth that of ideal plant working between the same temperatures. The power required to drive the plant is 3.72 kW 7.44 kW 1.86 kW 18.6 kW 3.72 kW 7.44 kW 1.86 kW 18.6 kW ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning When the air is passed through an insulated chamber having sprays of water maintained at a temperature higher than the dew point temperature of entering air but lower than its dry bulb temperature, then the air is said to be Heated and dehumidified Cooled and dehumidified Heated and humidified Cooled and humidified Heated and dehumidified Cooled and dehumidified Heated and humidified Cooled and humidified ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Which of the following statement is wrong? The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region None of the listed here The value of C.O.P. is always greater than one In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region None of the listed here The value of C.O.P. is always greater than one In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour ANSWER DOWNLOAD EXAMIANS APP