Refrigeration and Air Conditioning The coefficient of performance of Electrolux refrigerator is the ratio of Heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner to the heat absorbed by the evaporator Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator to the heat supplied by the gas burner Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The thermostatic expansion valve is used in ________ type of evaporators. DX coil None of these Dry Flooded DX coil None of these Dry Flooded ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Which of the following refrigerant has the highest freezing point. Carbon dioxide R-12 Ammonia Sulphur dioxide Carbon dioxide R-12 Ammonia Sulphur dioxide ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Bell Coleman cycle is a Reversed Carnot cycle Reversed Joule cycle Reversed Otto cycle Reversed Rankine cycle Reversed Carnot cycle Reversed Joule cycle Reversed Otto cycle Reversed Rankine cycle ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Which of the following statement is wrong? The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region None of the listed here In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour The value of C.O.P. is always greater than one The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region None of the listed here In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour The value of C.O.P. is always greater than one ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In a refrigeration cycle, the flow of refrigerant is controlled by Evaporator Compressor Expansion valve Condenser Evaporator Compressor Expansion valve Condenser ANSWER DOWNLOAD EXAMIANS APP