Refrigeration and Air Conditioning The coefficient of performance (C.O.P.) of a refrigerator working as a heat pump is given by ( O.P.)R + 2 O.P.)P = ( O.P)P = ( ( ( O.P)R O.P)P = ( O.P.)R + 1 ( O.P)R - 1 O.P.)P = ( ( O.P.)R + 2 O.P.)P = ( O.P)P = ( ( ( O.P)R O.P)P = ( O.P.)R + 1 ( O.P)R - 1 O.P.)P = ( ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning On the pressure-enthalpy diagram, condensation and desuperheating is represented by a horizontal line because the process Involves no change in volume Takes place at constant entropy Takes place at constant pressure Takes place at constant temperature Involves no change in volume Takes place at constant entropy Takes place at constant pressure Takes place at constant temperature ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In vapour compression cycle, the condition of refrigerant is high pressure saturated liquid After passing through the expansion or throttle valve Before passing through the condenser After passing through the condenser Before entering the expansion valve After passing through the expansion or throttle valve Before passing through the condenser After passing through the condenser Before entering the expansion valve ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The bypass factor of a cooling coil decreases with Decrease in fin spacing and increase in number of rows Increase in fin spacing and decrease in number of rows Increase in fin spacing and increase in number of rows Decrease in fin spacing and decrease in number of rows Decrease in fin spacing and increase in number of rows Increase in fin spacing and decrease in number of rows Increase in fin spacing and increase in number of rows Decrease in fin spacing and decrease in number of rows ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The bypass factor (B. P. F.) in case of sensible heating of air is (Where td₁ = Dry bulb temperature of air entering the heating coil, td₂ = Dry bulb temperature of air leaving the heating coil, and td₃ = Dry bulb temperature of heating coil) (td₃ - td₂)/(td₃ - td₁) (td₃ - td₁)/(td₃ - td₂) (td₂ - td₃)/(td₃ - td₁) (td₃ - td₁)/(td₂ - td₃) (td₃ - td₂)/(td₃ - td₁) (td₃ - td₁)/(td₃ - td₂) (td₂ - td₃)/(td₃ - td₁) (td₃ - td₁)/(td₂ - td₃) ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In vapour compression refrigeration system, refrigerant occurs as liquid between Compressor and condenser Condenser and expansion valve Compressor and evaporator Expansion valve and evaporator Compressor and condenser Condenser and expansion valve Compressor and evaporator Expansion valve and evaporator ANSWER DOWNLOAD EXAMIANS APP