Refrigeration and Air Conditioning The capillary tube is not used in large capacity refrigeration systems because Capacity control is not possible It is made of copper Required pressure drop cannot be achieved Cost is too high Capacity control is not possible It is made of copper Required pressure drop cannot be achieved Cost is too high ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The coefficient of performance of Electrolux refrigerator is the ratio of Heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator minus the heat supplied by the gas burner to the heat absorbed by the evaporator Heat absorbed by the evaporator to the heat supplied by the gas burner Heat supplied by the gas burner minus the heat absorbed by the evaporator to the heat supplied by the gas burner ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning During sensible cooling of air, specific humidity Increases Remains constant None of the listed here Decreases Increases Remains constant None of the listed here Decreases ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The specific humidity during heating and humidification process. None of these Remains constant Increases Decreases None of these Remains constant Increases Decreases ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The reciprocating refrigerant compressors are very suitable for Large displacements and low condensing pressures Large displacements and high condensing pressures Small displacements and low condensing pressures Small displacements and high condensing pressures Large displacements and low condensing pressures Large displacements and high condensing pressures Small displacements and low condensing pressures Small displacements and high condensing pressures ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In vapour compression refrigeration system, refrigerant occurs as liquid between Compressor and condenser Expansion valve and evaporator Compressor and evaporator Condenser and expansion valve Compressor and condenser Expansion valve and evaporator Compressor and evaporator Condenser and expansion valve ANSWER DOWNLOAD EXAMIANS APP