 Split-phase, capacitor, and shaded-pole single-phase motors classified as:

A.C. series motors
Repulsion motors
1-phase induction motors
Un-excited synchronous motors

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

SSC JE Electrical 2019 with solution SET-1
  In a capacitor start single phase induction motor the current in the:

Starting winding lags the voltage
The main winding leads the voltage
Starting winding leads the voltage
Supply lines lead the voltage

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

SSC JE Electrical 2019 with solution SET-1
 The resistive component of the rotor with resistance R2 offered to the backward rotating flux wave in a single-phase motor runs with slip s is given as

R2 ⁄ S
R2 ⁄ (1 + S)
R2 ⁄ (2 − S)
R2 ⁄ (1 − S)

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

SSC JE Electrical 2019 with solution SET-1
 For a three-layer stranded wire, the number of strands in the first, second, and third layer respectively are:

1, 7 and 14
1, 5 and 10
1, 4 and 8
1, 6 and 12

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

SSC JE Electrical 2019 with solution SET-1
 If dΦ is the luminous flux incident normally on an area dA, then Illuminance is given as

dΦ ⁄ dA
dΦ − dA
Φ × A
dA ⁄ dΦ

ANSWER EXPLANATION DOWNLOAD EXAMIANS APP

SSC JE Electrical 2019 with solution SET-1
 If the copper loss of a transformer at half full load is 400 W, then the copper loss corresponding to full load is

1600 W
1200 W
400 W
800 W