Electrical Machines Reversing the direction of rotation of split phase motors is done by reversing the terminals of main winding. interchanging the capacitor from starting winding to main winding or vice versa. All of these reversing the terminals of starting winding. reversing the terminals of main winding. interchanging the capacitor from starting winding to main winding or vice versa. All of these reversing the terminals of starting winding. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The interpoles in dc machines have a tapering shape in order to increase the acceleration of commutation economise on the material required for interpoles and their windings reduce the saturation in the interpole reduce the overall weight increase the acceleration of commutation economise on the material required for interpoles and their windings reduce the saturation in the interpole reduce the overall weight ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Which of the following machines have highest power factor with respect to magnetizing current? Open slot type machines. Any of the above. Semi closed slot type machine. Closed slot type machines. Open slot type machines. Any of the above. Semi closed slot type machine. Closed slot type machines. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Conservator tank is used None of these to take up the expansion of oil due to temperature rise. to act as an oil storage. for better cooling of transformer. None of these to take up the expansion of oil due to temperature rise. to act as an oil storage. for better cooling of transformer. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A dc shunt generator, when driven without any excitation, showed an open circuit voltage of 12 V. When the field winding was excited, the voltage dropped to zero. It happened because field winding was wrongly connected field resistance was higher than critical resistance there was no residual magnetism in the field circuit there was a break in the armature circuit field winding was wrongly connected field resistance was higher than critical resistance there was no residual magnetism in the field circuit there was a break in the armature circuit ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The result of slip test on a 3-phase, 20 KVA, 400 V, 50 Hz connected salient pole alternator is given below- Phase value: Vmax = 100 V, Vmin = 96 V, Imax = 10 A and I min = 7 A. The direct and quadranature axis reactances are respectively 8.248 and 5.54 Ω. 14.28 and 9.60 Ω. 8.248 and 9.60 Ω. 14.28 and 5.54 Ω. 8.248 and 5.54 Ω. 14.28 and 9.60 Ω. 8.248 and 9.60 Ω. 14.28 and 5.54 Ω. ANSWER DOWNLOAD EXAMIANS APP