Refrigeration and Air Conditioning Pick up the correct statement about giving up of heat from one medium to other in ammonia absorption system Strong solution to weak solution Weak solution to strong solution Strong solution to ammonia vapour Ammonia vapours to weak solution Strong solution to weak solution Weak solution to strong solution Strong solution to ammonia vapour Ammonia vapours to weak solution ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The sensible heat factor during cooling and dehumidification process is given by (where h₁ = Enthalpy of air entering the cooling coil, h₂ = Enthalpy of air leaving the cooling coil, and hA = Enthalpy of air at the end of dehumidification process) (h1 - h2)/ (hA - h2) (hA - h1)/ (h2 - h1) (h2 - hA)/ (h1 - h2) (hA - h2)/ (h1 - h2) (h1 - h2)/ (hA - h2) (hA - h1)/ (h2 - h1) (h2 - hA)/ (h1 - h2) (hA - h2)/ (h1 - h2) ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In order to cool and dehumidify a stream of moist air, it must be passed over the coil at a temperature Of adiabatic saturation of incoming stream Which lies between the wet bulb and dew point temperatures of the incoming stream Which is lower than the dew point temperature of the incoming stream Which lies between the dry bulb and wet bulb temperatures of the incoming stream Of adiabatic saturation of incoming stream Which lies between the wet bulb and dew point temperatures of the incoming stream Which is lower than the dew point temperature of the incoming stream Which lies between the dry bulb and wet bulb temperatures of the incoming stream ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The wet bulb depression indicates _________ humidity of the air. Specific None of these Relative Absolute Specific None of these Relative Absolute ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The operating temperature of a cold storage is -2°C. The heat leakage from the surrounding is 30 kW for the ambient temperature of 40°C. The actual C.O.P. of refrigeration plant used is one fourth that of ideal plant working between the same temperatures. The power required to drive the plant is 18.6 kW 3.72 kW 7.44 kW 1.86 kW 18.6 kW 3.72 kW 7.44 kW 1.86 kW ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A condenser of refrigeration system rejects heat at the rate of 120 kW, while its compressor consumes a power of 30 kW. The coefficient of performance of the system will be 3 4 43834 43833 3 4 43834 43833 ANSWER DOWNLOAD EXAMIANS APP