Concrete Technology and Design of Concrete Structures Minimum thickness of load bearing RCC wall should be 100 mm 105 mm 50 mm 40 mm 100 mm 105 mm 50 mm 40 mm ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Due to circumferential action of the spiral in a spirally reinforced column Capacity of column is decreased Both the capacity of column and ductility of column increase Ductility of column reduces Capacity of column is decreased but ductility of column increases Capacity of column is decreased Both the capacity of column and ductility of column increase Ductility of column reduces Capacity of column is decreased but ductility of column increases ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Assertion A : The load factor for live load is greater than that for dead load.Reason R : The live loads are more uncertain than dead loads.Select your answer based on the coding system given below : A is false but R is true. Both A and R are true and R is the correct explanation of A. A is true but R is false. Both A and R are true but R is not the correct explanation of A. A is false but R is true. Both A and R are true and R is the correct explanation of A. A is true but R is false. Both A and R are true but R is not the correct explanation of A. ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures The property of the ingredients to separate from each other while placing the concrete is called compaction segregation shrinkage bulking compaction segregation shrinkage bulking ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures Examine the following statements :i) Factor of safety for steel should be based on its yield stress,ii) Factor of safety for steel should be based on its ultimate stress,iii) Factor of safety for concrete should be based on its yield stress,iv) Factor of safety for concrete should be based on its ultimate stress.The correct statements are (i) and (iii) (i) and (iv) (ii) and (iv) (ii) and (iii) (i) and (iii) (i) and (iv) (ii) and (iv) (ii) and (iii) ANSWER DOWNLOAD EXAMIANS APP
Concrete Technology and Design of Concrete Structures In counterfort type retaining walls i) the vertical slab is designed as a continuous slab ii) the heel slab is designed as a continuous slab iii) the vertical slab is designed as a cantilever iv) the heel slab is designed as a cantilever The correct answer is (i) and (ii) (iii) and (iv) (ii) and (iii) (i) and (iv) (i) and (ii) (iii) and (iv) (ii) and (iii) (i) and (iv) ANSWER DOWNLOAD EXAMIANS APP