Electrical Machines Induction motors have the advantage of less maintenance. simple in construction. less cost. all of below. less maintenance. simple in construction. less cost. all of below. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Dissolve gas analysis of transformer oil is carried out to determine condition of transformer oil. condition of transformer. condition of bushings. condition of bushing stud. condition of transformer oil. condition of transformer. condition of bushings. condition of bushing stud. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines The demagnetising component of armature reaction in a DC generator reduces generator emf. increases armature speed. results in sparking trouble. reduces inter poles flux density. reduces generator emf. increases armature speed. results in sparking trouble. reduces inter poles flux density. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Short circuit test is performed on a transformer with a certain impressed voltage at rated frequency. If the short circuit test is now performed with the same magnitude of impressed voltage, but at frequency higher than the rated frequency then The magnitude of circuit as well as the power factor will decrease. The magnitude of current will decrease but the power factor will increase. The magnetude of current will increase, but power factor will decrease. The magnitude will both increase. The magnitude of circuit as well as the power factor will decrease. The magnitude of current will decrease but the power factor will increase. The magnetude of current will increase, but power factor will decrease. The magnitude will both increase. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A 4 pole dynamo with wave wound armature has 51 slots contains 20 conductors in each slot. If induced emf 357 Volts and speed is 8500 rpm, flux per pole will be 1.2 mWb. 1.4 mWb. 3.5 mWb. 2.7 mWb. 1.2 mWb. 1.4 mWb. 3.5 mWb. 2.7 mWb. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Two synchronous generators operating in parallel 200 MW and 400 MW respectively. The drooping characteristics of their governors are identical as 4% from no load to full load. Consider the governors operating at 50Hz on no load. How will the machine share, if the load is 600 MW? generator 1 gets over load generator 2 gets over load 200 MW and 400MW respectively 230.7 MW and 369.23 MW respectively generator 1 gets over load generator 2 gets over load 200 MW and 400MW respectively 230.7 MW and 369.23 MW respectively ANSWER DOWNLOAD EXAMIANS APP