Refrigeration and Air Conditioning In a vapour compression system, the condition of refrigerant is dry saturated vapour Before entering the compressor After leaving the condenser Before entering the condenser After leaving the compressor Before entering the compressor After leaving the condenser Before entering the condenser After leaving the compressor ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Which of the following statement is wrong? None of the listed here The value of C.O.P. is always greater than one The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour None of the listed here The value of C.O.P. is always greater than one The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A thermostatic expansion valve in a refrigeration system Is suitable only for constant load systems Maintains different temperatures in evaporator in proportion to load None of these Ensures the evaporator completely filled with refrigerant of the load Is suitable only for constant load systems Maintains different temperatures in evaporator in proportion to load None of these Ensures the evaporator completely filled with refrigerant of the load ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The operating temperature of a cold storage is -2°C. The heat leakage from the surrounding is 30 kW for the ambient temperature of 40°C. The actual C.O.P. of refrigeration plant used is one fourth that of ideal plant working between the same temperatures. The power required to drive the plant is 3.72 kW 1.86 kW 18.6 kW 7.44 kW 3.72 kW 1.86 kW 18.6 kW 7.44 kW ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A refrigerating system operating on reversed Brayton refrigeration cycle is used for maintaining 250 K. If the temperature at the end of constant pressure cooling is 300 K and rise in the temperature of air in the refrigerator is 50 K, then the net work of compression will be (assume air as working substance with Cp = 1 kJ/kg) 50 kJ/kg 100 kJ/kg 125 kJ/kg 25 kJ/kg 50 kJ/kg 100 kJ/kg 125 kJ/kg 25 kJ/kg ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In a vapour compression refrigeration system, a throttle valve is used in place of an expander because It considerably reduces mass of the system It improves the C.O.P., as the condenser is small The positive work in isentropic expansion of liquid is very small It leads to significant cost reduction It considerably reduces mass of the system It improves the C.O.P., as the condenser is small The positive work in isentropic expansion of liquid is very small It leads to significant cost reduction ANSWER DOWNLOAD EXAMIANS APP