Refrigeration and Air Conditioning In a domestic refrigerator, a capillary tube controls the flow of refrigerant from the Expansion valve to the evaporator Condenser to the expansion valve Evaporator to the thermostat Condenser to the evaporator Expansion valve to the evaporator Condenser to the expansion valve Evaporator to the thermostat Condenser to the evaporator ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The refrigerant after condensation process is cooled below the saturation temperature before throttling. Such a process is called Sub-cooling or under-cooling None of the listed here Super-cooling Normal cooling Sub-cooling or under-cooling None of the listed here Super-cooling Normal cooling ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The sensible heat factor during cooling and dehumidification process is given by (where h₁ = Enthalpy of air entering the cooling coil, h₂ = Enthalpy of air leaving the cooling coil, and hA = Enthalpy of air at the end of dehumidification process) (h2 - hA)/ (h1 - h2) (hA - h1)/ (h2 - h1) (hA - h2)/ (h1 - h2) (h1 - h2)/ (hA - h2) (h2 - hA)/ (h1 - h2) (hA - h1)/ (h2 - h1) (hA - h2)/ (h1 - h2) (h1 - h2)/ (hA - h2) ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A standard ice point temperature corresponds to the temperature of Mixture of ice and water under equilibrium conditions Ice at 4°C Solid and dry ice Water at 0°C Mixture of ice and water under equilibrium conditions Ice at 4°C Solid and dry ice Water at 0°C ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The condensing pressure due to the presence of non-condensable gases, as compared to that actually required for condensing temperatures without non-condensable gases, Will be lower May be higher or lower depending upon the nature of non-condensable gases Will remain unaffected Will be higher Will be lower May be higher or lower depending upon the nature of non-condensable gases Will remain unaffected Will be higher ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Which of the following statement is wrong? The value of C.O.P. is always greater than one None of the listed here In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region The value of C.O.P. is always greater than one None of the listed here In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region ANSWER DOWNLOAD EXAMIANS APP