Refrigeration and Air Conditioning In a domestic refrigerator, a capillary tube controls the flow of refrigerant from the Evaporator to the thermostat Expansion valve to the evaporator Condenser to the expansion valve Condenser to the evaporator Evaporator to the thermostat Expansion valve to the evaporator Condenser to the expansion valve Condenser to the evaporator ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The sensible heat factor during cooling and dehumidification process is given by (where h₁ = Enthalpy of air entering the cooling coil, h₂ = Enthalpy of air leaving the cooling coil, and hA = Enthalpy of air at the end of dehumidification process) (hA - h1)/ (h2 - h1) (hA - h2)/ (h1 - h2) (h1 - h2)/ (hA - h2) (h2 - hA)/ (h1 - h2) (hA - h1)/ (h2 - h1) (hA - h2)/ (h1 - h2) (h1 - h2)/ (hA - h2) (h2 - hA)/ (h1 - h2) ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The ratio of actual mass of water vapour in a given volume of moist air to the mass of water vapour in the same volume of saturated air at the same temperature and pressure, is called Humidity ratio Degree of saturation Absolute humidity Relative humidity Humidity ratio Degree of saturation Absolute humidity Relative humidity ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning Dry bulb temperature is the temperature of air recorded by a thermometer, when It is not affected by the moisture present in the air Its bulb is surrounded by a wet cloth exposed to the air The moisture present in it begins to condense None of the listed here It is not affected by the moisture present in the air Its bulb is surrounded by a wet cloth exposed to the air The moisture present in it begins to condense None of the listed here ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning In vapour compression refrigeration system, refrigerant occurs as liquid between Compressor and evaporator Compressor and condenser Expansion valve and evaporator Condenser and expansion valve Compressor and evaporator Compressor and condenser Expansion valve and evaporator Condenser and expansion valve ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning R-12 is generally preferred over R-22 in deep freezers since It is miscible with oil over large range of temperatures All of these It gives higher coefficient of performance It has low operating pressures It is miscible with oil over large range of temperatures All of these It gives higher coefficient of performance It has low operating pressures ANSWER DOWNLOAD EXAMIANS APP