Structural Analysis If the specified thickness of a footing is 100 cm, the depth of the form work may be tolerated from -3 mm to +3 mm -4 mm to +4 mm -5 mm to +5 mm -2 mm to +2 mm -3 mm to +3 mm -4 mm to +4 mm -5 mm to +5 mm -2 mm to +2 mm ANSWER DOWNLOAD EXAMIANS APP
Structural Analysis The effective and actual lengths of a cantilever are same if continuous at the support, Restrained against torsion at the support and free at the end None of these With partial restraint against torsion of the support and free at the end Unstrained against torsion at the support and free at the end Restrained against torsion at the support and free at the end None of these With partial restraint against torsion of the support and free at the end Unstrained against torsion at the support and free at the end ANSWER DOWNLOAD EXAMIANS APP
Structural Analysis The deflection at any point of a perfect frame can be obtained by applying a unit load at the joint in The direction in which the deflection is required Vertical direction Horizontal direction Inclined direction The direction in which the deflection is required Vertical direction Horizontal direction Inclined direction ANSWER DOWNLOAD EXAMIANS APP
Structural Analysis A rigid-jointed plane frame is stable and statically determinate if (where m is number of members, r is reaction components and j is number of joints) (m + 3r) = 3j (3m + r) = 3j (m + r) = 3j (m + r) = 2j (m + 3r) = 3j (3m + r) = 3j (m + r) = 3j (m + r) = 2j ANSWER DOWNLOAD EXAMIANS APP
Structural Analysis For stable structures, one of the important properties of flexibility and stiffness matrices is that the elements on the main diagonal (i) Of a stiffness matrix must be positive (ii) Of a stiffness matrix must be negative (iii) Of a flexibility matrix must be positive (iv) Of a flexibility matrix must be negative The correct answer is (ii) and (iv) (i) and (iii) (ii) and (iii) (i) and (iv) (ii) and (iv) (i) and (iii) (ii) and (iii) (i) and (iv) ANSWER DOWNLOAD EXAMIANS APP
Structural Analysis For under water concreting. All of these The volume of coarse aggregates shall not be less than one and half times and not more than twice that of fine aggregate De-watering by pumping is not done or until 24 hours thereafter At least 10 percent more cement is required as compared to dry conditions All of these The volume of coarse aggregates shall not be less than one and half times and not more than twice that of fine aggregate De-watering by pumping is not done or until 24 hours thereafter At least 10 percent more cement is required as compared to dry conditions ANSWER DOWNLOAD EXAMIANS APP