DGVCL Exam Paper (11-12-2011) If the dielectric strength of the medium between the contacts builds up more rapidly than the restriking voltage the arc will Decrease in size Restrike Extinguish Increase in size Decrease in size Restrike Extinguish Increase in size ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) If the voltage at the two ends of a line are 132 kV, and its reactance is 40 Ω, the stability limit of the line is 251.5 MW 217.8 MW 500 MW 435.6 MW 251.5 MW 217.8 MW 500 MW 435.6 MW ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) What happens to the contents of RAM (Random Access Memory) when the power of the computer is turned off? Content remains intact Content is transferred to other memory Content gets corrupted Content is lost Content remains intact Content is transferred to other memory Content gets corrupted Content is lost ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) If the percentage reactance of the system upto the point of fault is 20% and the base kVA is 10,000 the short ciruit kVA is 60 MVA 50 MVA 10 MVA 20 MVA 60 MVA 50 MVA 10 MVA 20 MVA ANSWER EXPLANATION DOWNLOAD EXAMIANS APP Short circuit kVA = Base kVA/%X
DGVCL Exam Paper (11-12-2011) Reactance relay is used to protect against Both phase and earth faults Phase faults only Over voltage faults Earth faults only Both phase and earth faults Phase faults only Over voltage faults Earth faults only ANSWER DOWNLOAD EXAMIANS APP
DGVCL Exam Paper (11-12-2011) It is difficult interrupt a capacitive current because Stored energy in the capacitor is very high The restriking voltage can be high It has a leading power factor Current magnitude is very small Stored energy in the capacitor is very high The restriking voltage can be high It has a leading power factor Current magnitude is very small ANSWER DOWNLOAD EXAMIANS APP