Power Systems If L and C are 4 mH and 0.0001 μF respectively a current chop of magnitude 50 Amp would induced a voltage 200 kV. 400 kV. 100 kV. 50 kV. 200 kV. 400 kV. 100 kV. 50 kV. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The factor affecting run off are all of above. rain fall pattern, shape and size of catchment area. amount of vegetation and weather condition in the catchment area. the topography and nature of soil in the catchment area. all of above. rain fall pattern, shape and size of catchment area. amount of vegetation and weather condition in the catchment area. the topography and nature of soil in the catchment area. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The line current IR flowing into balanced delta connected load is - j5 - 3 A. If the phase sequence is RYB the phase current IYB is 5. 20. 10. 55.1. 5. 20. 10. 55.1. ANSWER DOWNLOAD EXAMIANS APP
Power Systems What is the function of economiser in steam boilers improving thermal efficiency collect ash particals All of these cooling improving thermal efficiency collect ash particals All of these cooling ANSWER DOWNLOAD EXAMIANS APP
Power Systems The incremental fuel costs for two generating units G1 and G2 are given by Ic1 = 25 + 0.2 PG1 and Ic2 = 32 + 0.2 PG2, where PG1 and PG2 are real powers generated by the units. The economic allocation for a total load of 250 MW, neglecting transmission loss, is given by PG1 = 109.75 MW and PG2 = 140.25 MW PG1 = 125 MW and PG2 = 125 MW PG1 = 100 MW and PG2 = 150 MW PG1 = 142.5 MW and PG2 = 107.5 MW PG1 = 109.75 MW and PG2 = 140.25 MW PG1 = 125 MW and PG2 = 125 MW PG1 = 100 MW and PG2 = 150 MW PG1 = 142.5 MW and PG2 = 107.5 MW ANSWER DOWNLOAD EXAMIANS APP
Power Systems Which of the following is not a secondary nuclear fuel None of above. U233. U235. Pu239. None of above. U233. U235. Pu239. ANSWER DOWNLOAD EXAMIANS APP