Electrical Machines Breadth factor is defined as the ratio of emf with concentrated winding to emf with distributed winding. emf with distributed winding to emf with concentrated winding. both 1 and 2. None of these emf with concentrated winding to emf with distributed winding. emf with distributed winding to emf with concentrated winding. both 1 and 2. None of these ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A 400 V, 50 Hz, 30 Hp, three phase IM is drawing 50 A current at 0.8 p.f lagging. The stator and rotor copper losses are 1.5 KW and 900 W respectively. The friction and windage losses are 1050 W and core losses are 1200 W. The air gap power of the motor will be 23.06 kW. 24.11 kW. 26.21 kW. 25 kW. 23.06 kW. 24.11 kW. 26.21 kW. 25 kW. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines In a synchronous motor when the rotor speed exceeds the synchronous speed during hunting negative sequence currents are generated. the damper bars develop induction generator torque. the damper bars develop synchronous motor torque. the damper bars develop induction motor torque. negative sequence currents are generated. the damper bars develop induction generator torque. the damper bars develop synchronous motor torque. the damper bars develop induction motor torque. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A dc shunt motor has external resistance Ra and Rf in the armature and field circuits respectively. Armature current at starting can be reduced by keeping Rf maximum and Ra minimum Ra minimum and Rf minimum Ra maximum and Rf maximum Ra maximum and Rf minimum Rf maximum and Ra minimum Ra minimum and Rf minimum Ra maximum and Rf maximum Ra maximum and Rf minimum ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A dc shunt generator, when commissioned after a major repair of the field system, failed to build Up voltage. It was because there was a break in the armature circuit field system lost residual magnetism field resistance was higher than critical resistance field winding was wrongly connected there was a break in the armature circuit field system lost residual magnetism field resistance was higher than critical resistance field winding was wrongly connected ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines If a transformer has turns ratio K, the primary and secondary current are I1 and I2 respectively and magnetizing current and core loss component of no load current Iμ and Iw respectively, then I1 = KI2 + Iw. I1 = KI2 + Iμ. I1 = KI2 + Iw + Iμ.ok I1 = KI2. I1 = KI2 + Iw. I1 = KI2 + Iμ. I1 = KI2 + Iw + Iμ.ok I1 = KI2. ANSWER DOWNLOAD EXAMIANS APP