Power Systems Attenuation occurs due to inductance both 1 and 3 resistance conductance inductance both 1 and 3 resistance conductance ANSWER DOWNLOAD EXAMIANS APP
Power Systems A 50 Hz, 17.32 kV generator is connected to a power system. The system reactance and capacitance per phase are 10 mH and 0.2 mF respectively. What is the maximum voltage across the contacts of the circuit breaker at an instant when it passes through zero? 29.28 kV 31.28 kV 28.28 kV 30.28 kV 29.28 kV 31.28 kV 28.28 kV 30.28 kV ANSWER DOWNLOAD EXAMIANS APP
Power Systems Which of the following circuit breakers produce least arc energy? Minimum oil CB. Plain oil CB. Air blast CB. Air break CB. Minimum oil CB. Plain oil CB. Air blast CB. Air break CB. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The incremental fuel costs for two generating units G1 and G2 are given by Ic1 = 25 + 0.2 PG1 and Ic2 = 32 + 0.2 PG2, where PG1 and PG2 are real powers generated by the units. The economic allocation for a total load of 250 MW, neglecting transmission loss, is given by PG1 = 142.5 MW and PG2 = 107.5 MW PG1 = 125 MW and PG2 = 125 MW PG1 = 109.75 MW and PG2 = 140.25 MW PG1 = 100 MW and PG2 = 150 MW PG1 = 142.5 MW and PG2 = 107.5 MW PG1 = 125 MW and PG2 = 125 MW PG1 = 109.75 MW and PG2 = 140.25 MW PG1 = 100 MW and PG2 = 150 MW ANSWER DOWNLOAD EXAMIANS APP
Power Systems Main bus bar protection scheme is /are none of these. differential protection. fault bus protection. both fault bus and differential protection. none of these. differential protection. fault bus protection. both fault bus and differential protection. ANSWER DOWNLOAD EXAMIANS APP
Power Systems A 3-phase transmission line operating at Vs = 400 kV and has ABCD parameters A= D = 0.8∠0°, B = 100∠90° Ω, C = 0.5*10-6∠90° â„§. Find the no load receiving end voltage? 600 kV 500 kV 400 kV 320 kv 600 kV 500 kV 400 kV 320 kv ANSWER DOWNLOAD EXAMIANS APP