Electrical Machines A 3 - φ induction motor can also be referred to as a repulsion motor. shunt motor. transformer. asynchronous motor. repulsion motor. shunt motor. transformer. asynchronous motor. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines What will be the maximum power factor of an induction motor for dispersion coefficient of 0.05? 20. 0.905. 1.1. 0.05. 20. 0.905. 1.1. 0.05. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Series generators are used in which of the following applications? All of these Arc welding. Air crafts. Used as boosters in dc distribution or transmission. All of these Arc welding. Air crafts. Used as boosters in dc distribution or transmission. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines During hunting of a synchronous motor negative phase sequence currents are generated. damper bar develops torque. harmonic are developed in the armature circuit. field excitation increases. negative phase sequence currents are generated. damper bar develops torque. harmonic are developed in the armature circuit. field excitation increases. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Induction motors have the advantage of less cost. less maintenance. all of below. simple in construction. less cost. less maintenance. all of below. simple in construction. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A 400 V, 50 Hz, 30 Hp, three phase IM is drawing 50 A current at 0.8 p.f lagging. The stator and rotor copper losses are 1.5 KW and 900 W respectively. The friction and windage losses are 1050 W and core losses are 1200 W. The air gap power of the motor will be 24.11 kW. 23.06 kW. 25 kW. 26.21 kW. 24.11 kW. 23.06 kW. 25 kW. 26.21 kW. ANSWER DOWNLOAD EXAMIANS APP