Measurement and Instrumentation A 150 V moving iron voltmeter of accuracy class 1-0 reads 75 V when used in a circuit under standard condition. The maximum possible percentage error in the reading is 1.5% 2.5% 2% 1% 1.5% 2.5% 2% 1% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The total current I = I1 + I2 in a circuit is measured as I1 = 150 ± 1A , I2 = 250 ± 2A, where the limits of error are as standard deviations. I is measured as (400 ± 3) A (400 ± 2.24) A (400 ± 1.5) A (400 ± 1) A (400 ± 3) A (400 ± 2.24) A (400 ± 1.5) A (400 ± 1) A ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation Jewels are used in instruments for the purpose of Torque control Suppressing noise Damping Bearing Torque control Suppressing noise Damping Bearing ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation Unit of deflection sensitivity of a CRO is mm / V. V / mm. meter / volt. mm per mV. mm / V. V / mm. meter / volt. mm per mV. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation For a circuit given that I = 2 ± 5 % A, R = 100 ± 0.2 % Ω the limiting error in the power dissipation I2 R in the resistor R is 1.2% 10.2% 25.2% 5.2% 1.2% 10.2% 25.2% 5.2% ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation To measure the flux, devices used are based on Voltaic effect Piezo-electric effect Hall effect Photo-voltaic effect Voltaic effect Piezo-electric effect Hall effect Photo-voltaic effect ANSWER DOWNLOAD EXAMIANS APP