Electrical Machines Which of the following statements is/are correct statements? All of these EMF per turn in both the windings are equal EMF per turn in HV winding is more than EMF per turn in LV winding EMF per turn in HV winding is less than EMF per turn in LV winding All of these EMF per turn in both the windings are equal EMF per turn in HV winding is more than EMF per turn in LV winding EMF per turn in HV winding is less than EMF per turn in LV winding ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines 3rd harmonics are eliminated in induction motor by using star connection. delta connection. zig - zag connection. V connection. star connection. delta connection. zig - zag connection. V connection. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A single phase transformer has specifications as 250 KVA, 11000 V/415 V, 50 Hz. What are the values of primary and secondary currents? primary = 11.4 A, secondary = 301 A primary = 301 A, secondary = 22.7 A primary = 602 A, secondary = 22.7 A primary = 22.7 A, secondary = 602.4 A primary = 11.4 A, secondary = 301 A primary = 301 A, secondary = 22.7 A primary = 602 A, secondary = 22.7 A primary = 22.7 A, secondary = 602.4 A ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Synchronous condensers are used to reduce hunting improve starting torque improve the power factor All of these reduce hunting improve starting torque improve the power factor All of these ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines Short circuit test is performed on a transformer with a certain impressed voltage at rated frequency. If the short circuit test is now performed with the same magnitude of impressed voltage, but at frequency higher than the rated frequency then The magnitude will both increase. The magnitude of current will decrease but the power factor will increase. The magnitude of circuit as well as the power factor will decrease. The magnetude of current will increase, but power factor will decrease. The magnitude will both increase. The magnitude of current will decrease but the power factor will increase. The magnitude of circuit as well as the power factor will decrease. The magnetude of current will increase, but power factor will decrease. ANSWER DOWNLOAD EXAMIANS APP
Electrical Machines A single phase, 2 KV alternator has an armature resistance of 0.8 ohms and 4.94 ohms respectively. The voltage regulation of the alternator at 100 a load 0.8 loading power factor is 7%. 8.9%. 0%. 14%. 7%. 8.9%. 0%. 14%. ANSWER DOWNLOAD EXAMIANS APP