Refrigeration and Air Conditioning Which of the following statement is wrong? None of the listed here In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region The value of C.O.P. is always greater than one None of the listed here In a vapour compression system, the condition of refrigerant before entering the compressor is dry saturated vapour The space between the saturated liquid line and saturated vapour line, in a pressure enthalpy chart, is wet vapour region The value of C.O.P. is always greater than one ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The temperature of air recorded by a thermometer, when it is not affected by the moisture present in the air, is called Wet bulb temperature None of these Dry bulb temperature Dew point temperature Wet bulb temperature None of these Dry bulb temperature Dew point temperature ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The coefficient of performance (C.O.P.) of a refrigerator working as a heat pump is given by O.P.)R + 1 ( ( O.P)P = ( ( O.P)P = ( O.P.)P = ( O.P)R - 1 O.P)R O.P.)R + 2 O.P.)P = ( ( O.P.)R + 1 ( ( O.P)P = ( ( O.P)P = ( O.P.)P = ( O.P)R - 1 O.P)R O.P.)R + 2 O.P.)P = ( ( ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The bypass factor, in case of sensible cooling of air, is given by (where td₁ = Dry bulb temperature of air entering the cooling coil, td₂ = Dry bulb temperature of air leaving the cooling coil, and td₃ = Dry bulb temperature of the cooling coil) (td₁ -td₃)/( td₂ -td₃) (td₂ -td₃)/( td₁ -td₃) (td₃ -td₁)/( td₂ -td₃) (td₃ -td₂)/( td₁ -td₃) (td₁ -td₃)/( td₂ -td₃) (td₂ -td₃)/( td₁ -td₃) (td₃ -td₁)/( td₂ -td₃) (td₃ -td₂)/( td₁ -td₃) ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning A refrigerating system operating on reversed Brayton refrigeration cycle is used for maintaining 250 K. If the temperature at the end of constant pressure cooling is 300 K and rise in the temperature of air in the refrigerator is 50 K, then the net work of compression will be (assume air as working substance with Cp = 1 kJ/kg) 25 kJ/kg 125 kJ/kg 100 kJ/kg 50 kJ/kg 25 kJ/kg 125 kJ/kg 100 kJ/kg 50 kJ/kg ANSWER DOWNLOAD EXAMIANS APP
Refrigeration and Air Conditioning The dry bulb temperature lines, on the psychrometric chart are Horizontal and non-uniformly spaced Curved lines Vertical and uniformly spaced Horizontal and uniformly spaced Horizontal and non-uniformly spaced Curved lines Vertical and uniformly spaced Horizontal and uniformly spaced ANSWER DOWNLOAD EXAMIANS APP