Process Control and Instrumentation Thermodynamic celcius scale of temperature measurement is Both A&B Here Having an interval of 100° between ice point to steam point Having an interval of 100° between ice point to steam point Defined on the basis of melting point of ice and evaporation temperature of water vapor Both A&B Here Having an interval of 100° between ice point to steam point Having an interval of 100° between ice point to steam point Defined on the basis of melting point of ice and evaporation temperature of water vapor ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation Temperature control of an exothermic chemical reaction taking place in a CSTR is done with the help of cooling water flowing in a jacket around the reactor. The types of valve and controller action to be recommended are Air to open valve with the controller indirect acting Air to close valve with the controller indirect acting Air to close valve with the controller direct acting Air to open valve with the controller direct acting Air to open valve with the controller indirect acting Air to close valve with the controller indirect acting Air to close valve with the controller direct acting Air to open valve with the controller direct acting ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation A bolometer is An element which senses optical input and delivers thermal output Neither A nor B Here Used for the measurement of thermal radiation Both A & B Here An element which senses optical input and delivers thermal output Neither A nor B Here Used for the measurement of thermal radiation Both A & B Here ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation Number of poles in a system with transfer function 1/(s² + 2s² + 1) is 5 2 1 3 5 2 1 3 ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation Temperature measurement range of iron-constantan thermocouple is 0 to 870°C. It can be used to measure sub zero temperature, because at lower temperature Embrittlement of iron occurs Rusting of iron takes place Both B and C Here Emf produced is very low of the order of microvolt Embrittlement of iron occurs Rusting of iron takes place Both B and C Here Emf produced is very low of the order of microvolt ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation When a bare thermocouple is covered by a protective sheath, the response becomes Faster and non-oscillatory Slower and non-oscillatory Slower and oscillatory Faster and oscillatory Faster and non-oscillatory Slower and non-oscillatory Slower and oscillatory Faster and oscillatory ANSWER DOWNLOAD EXAMIANS APP