Power Systems Pump storage schemes are used to improve the power factor. the load factor. the plant capacity factor as well as the load factor of the power system. the diversity factor. the power factor. the load factor. the plant capacity factor as well as the load factor of the power system. the diversity factor. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The value of off diagonal elements is sum of admittances connected at bus i sum of admittances connected at bus j which is connected between bus i and bus j with positive sign which is connected between bus i and bus j with negative sign sum of admittances connected at bus i sum of admittances connected at bus j which is connected between bus i and bus j with positive sign which is connected between bus i and bus j with negative sign ANSWER DOWNLOAD EXAMIANS APP
Power Systems Which one of following is employed as a moderator by CANDU type of slow thermal nuclear reactors Heavy water. Graphite. Beryllium. Water. Heavy water. Graphite. Beryllium. Water. ANSWER DOWNLOAD EXAMIANS APP
Power Systems The voltage regulation of a line at full load 0.8 power factor is 11. A long transmission line under no load conditions, for a good voltage profile needs All of these shunt capacitor at receiving end shunt resistance at receiving end shunt reactor at receiving end All of these shunt capacitor at receiving end shunt resistance at receiving end shunt reactor at receiving end ANSWER DOWNLOAD EXAMIANS APP
Power Systems Per unit of any quantity is defined as actual value of quantity /base value of quantity in different units actual value of quantity /base value of quantity in same units base value of quantity /actual value of quantity in different units base value of quantity /actual value of quantity in same units actual value of quantity /base value of quantity in different units actual value of quantity /base value of quantity in same units base value of quantity /actual value of quantity in different units base value of quantity /actual value of quantity in same units ANSWER DOWNLOAD EXAMIANS APP
Power Systems Consider a three phase, 50 Hz, 11 kV distribution system. Each of the conductors is suspended by an insulator string having two identical porcelain insulators. The self capacitance of the insulators is 5 times the shunt capacitance between the link and ground. Find the voltage across the two insulators V1 and V2? (V1 = Voltage of disc nearest to the conductor) V1 = 6 kV and V2 = 5 kV V1 = 3.46 kV and V2 = 2.89 kV V1 = 2.89 kV and V2 = 3.46 kV V1 = 5 kV and V2 = 6 kV V1 = 6 kV and V2 = 5 kV V1 = 3.46 kV and V2 = 2.89 kV V1 = 2.89 kV and V2 = 3.46 kV V1 = 5 kV and V2 = 6 kV ANSWER DOWNLOAD EXAMIANS APP