Measurement and Instrumentation Moving iron instruments have _____ scale. Log Squared None of the listed here Uniform Log Squared None of the listed here Uniform ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The total current I = I1 + I2 in a circuit is measured I1 = 150 ± 3A , I2 = 250 ± 4 A, where the limits of error are given as standard deviations. I is measured as (400 ± 3) A (400 ±5) A (400 ± 2.24) A (400 ± 1) A (400 ± 3) A (400 ±5) A (400 ± 2.24) A (400 ± 1) A ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation The quantity 1/√(∈0 × μ0) in SI units has the both ‘a’ and ‘b’. dimension LT-1. none of these. speed of light. both ‘a’ and ‘b’. dimension LT-1. none of these. speed of light. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A 0 - 100 V voltmeter has a guaranteed accuracy of 2 % of full scale reading. The voltage measured by the voltmeter is 75 V. The limiting error is in percentage 2.66 %. 1 %. 2 %. 3.33 %. 2.66 %. 1 %. 2 %. 3.33 %. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation A current of is measured with a thermocouple, 5 A full scale meter. What is the meter reading? 6.09 A. 5 A. 2.03 A. 4.06 A. 6.09 A. 5 A. 2.03 A. 4.06 A. ANSWER DOWNLOAD EXAMIANS APP
Measurement and Instrumentation If two meters X and Y require 40 mA and 50 mA respectively, to give full scale deflection, then Both X and Y are equally sensitive. It would not be possible to assess the sensitivity on the basis of the given data. X is more sensitive. Y is more sensitive. Both X and Y are equally sensitive. It would not be possible to assess the sensitivity on the basis of the given data. X is more sensitive. Y is more sensitive. ANSWER DOWNLOAD EXAMIANS APP