Process Control and Instrumentation Dead zone is the Same as time constant Maximum change in the variable that does not change the reading of the instrument Same as transportation lag None of these Same as time constant Maximum change in the variable that does not change the reading of the instrument Same as transportation lag None of these ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation Which thermocouple can be used to measure a temperature of around 1400°C ? Copper-constantan None of these Platinum-platinum+rhodium Aluminium-chromel Copper-constantan None of these Platinum-platinum+rhodium Aluminium-chromel ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation For two non-interacting first order systems connected in series, the overall transfer function is the __________ of the individual transfer functions. Ratio Product Sum Difference Ratio Product Sum Difference ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation Pick out the first order system from among the following. Mercury in glass thermometer kept in boiling water Interacting system of two tanks in series Damped vibrator Non-interacting system of two tanks in series Mercury in glass thermometer kept in boiling water Interacting system of two tanks in series Damped vibrator Non-interacting system of two tanks in series ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation Emf developed by a thermocouple while measuring a temperature of 400°C is 22 mV. The type of thermocouple used is Chromel-alumel Platinum-platinum+rhyodium Platinum-rhodium Iron-constantan Chromel-alumel Platinum-platinum+rhyodium Platinum-rhodium Iron-constantan ANSWER DOWNLOAD EXAMIANS APP
Process Control and Instrumentation The root locus plot of the roots of the characteristics equation of a closed loop system having the open loop transfer function K(s + 1)/2(2s + 1)(3s + 1) will have a definite number of loci for variation of K from 0 to ∞. The number of loci is 2 1 3 4 2 1 3 4 ANSWER DOWNLOAD EXAMIANS APP