Design of Masonry Structures Consider the following statements:A high lime content in a composite cement-lime mortar results in1. Slow hardening.2. Quick setting.3. Weaker mortar. 1, 2 and 3 are correct 1 and 2 are correct 1 and 3 are correct 2 and 3 are correct 1, 2 and 3 are correct 1 and 2 are correct 1 and 3 are correct 2 and 3 are correct ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures Assertion A : For identical strength, a composite cement-lime mortar is preferred over cement mortar.Reason R : Composite cement-lime mortar has higher drying shrinkage than cement mortar.Select your answer based on the codes given below. Codes: Both A and R is true and R is the correct explanation of A Both A and R is true but R is not a correct explanation of A A is false but R is true A is true but R is false Both A and R is true and R is the correct explanation of A Both A and R is true but R is not a correct explanation of A A is false but R is true A is true but R is false ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures If ‘H’ is the height of wall between centers of supports, then the effective height of wall where concrete floors have a bearing on wall irrespective of the direction of span will be 0.85 H 0.75 H 1.5 H 1.0 H 0.85 H 0.75 H 1.5 H 1.0 H ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures If the ratio of center to center spacing of intersecting walls to actual thickness of intersecting wall is more than 20, then the stiffening coefficient for wall proper will be 1 Between 0 and 1 Greater than 1 1 Between 0 and 1 Greater than 1 ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures Assertion A : Limiting value of slenderness ratio for a column is less than that of a wall.Reason R : A column can buckle around either of the two horizontal axes while a wall can buckle around only one axis.Select your answer according to the codes given below: A is true but R is false A is false but R is true Both A and R is true and R is the correct explanation of A Both A and R is true but R is not the correct explanation of A A is true but R is false A is false but R is true Both A and R is true and R is the correct explanation of A Both A and R is true but R is not the correct explanation of A ANSWER DOWNLOAD EXAMIANS APP
Design of Masonry Structures For earthquake resistant masonry buildings, where seismic coefficient is less than 0.08, the horizontal distance between two openings shall not be less than Vi x height of longer opening Ax height of shorter opening Vt x height of shorter opening Vt x height of longer opening Vi x height of longer opening Ax height of shorter opening Vt x height of shorter opening Vt x height of longer opening ANSWER DOWNLOAD EXAMIANS APP